{"id":1020,"date":"2019-09-16T21:27:29","date_gmt":"2019-09-16T16:57:29","guid":{"rendered":"https:\/\/imenariaharigh.com\/%d8%b3%db%8c%d8%b3%d8%aa%d9%85-%d8%a7%d8%b7%d9%81%d8%a7%d8%a1-%d8%a7%d8%aa%d9%88%d9%85%d8%a7%d8%aa%db%8c%da%a9-%d8%ba%db%8c%d8%b1-%d9%85%d8%b3%d8%aa%d9%82%db%8c%d9%85-firedetec-ihp\/"},"modified":"2019-09-21T23:20:54","modified_gmt":"2019-09-21T19:50:54","slug":"indirect-firefighting-system-firedetec-ihp","status":"publish","type":"post","link":"https:\/\/imenariaharigh.com\/en\/indirect-firefighting-system-firedetec-ihp\/","title":{"rendered":"Indirect Firefighting System FireDetec IHP"},"content":{"rendered":"<p dir=\"ltr\"><strong> <span class=\"fontstyle0\">ELECTRICAL CABINET SYSTEMS &#8211; INDIRECT<\/span> <\/strong><\/p>\n<p dir=\"ltr\"><span class=\"fontstyle0\">MINIMIZES RISK TO VITAL EQUIPMENT<br \/>\n<\/span><span class=\"fontstyle2\">&#8211; #1 Cause of Industrial Fires*<br \/>\n&#8211; 75% of total-loss fires start as an electrical fire*<br \/>\n&#8211; Helps minimize damage to vital electrical equipment<br \/>\n&#8211; Minimizes work stoppage during repairs\/cleanup<br \/>\n&#8211; Prevents extensive cleanup if the<br \/>\nsprinkler system discharges<\/span><\/p>\n<p dir=\"ltr\"><span class=\"fontstyle0\">KEY FEATURES<br \/>\n<\/span><span class=\"fontstyle2\">&#8211; A complete, ready-to-install system &#8211; all in one box<br \/>\n&#8211; Available with CO2 or HFC-227ea extinguishing agent<br \/>\n&#8211; Available in multiple cylinder sizes for<br \/>\nsmall, medium or large enclosures<br \/>\n&#8211; CO2 systems available with choice<br \/>\nof filled or unfilled cylinders<br \/>\n&#8211; HFC-227ea systems available filled<br \/>\nonly. Unfilled on request<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/rotarexfiretec.com\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-913 aligncenter\" src=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp-system.jpg\" alt=\"ihp system\" width=\"356\" height=\"389\" srcset=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp-system.jpg 594w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp-system-275x300.jpg 275w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp-system-1x1.jpg 1w\" sizes=\"auto, (max-width: 356px) 100vw, 356px\" \/><\/a><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-914\" src=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp-system-schematic.jpg\" alt=\"ihp system schematic\" width=\"1011\" height=\"656\" srcset=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp-system-schematic.jpg 1011w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp-system-schematic-300x195.jpg 300w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp-system-schematic-768x498.jpg 768w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp-system-schematic-2x1.jpg 2w\" sizes=\"auto, (max-width: 1011px) 100vw, 1011px\" \/><\/p>\n<p dir=\"ltr\"><strong>Consists of below:<\/strong><\/p>\n<table dir=\"ltr\">\n<tbody>\n<tr>\n<td width=\"26\">\n<p dir=\"ltr\" style=\"text-align: left;\"><strong>POS.<\/strong><\/p>\n<\/td>\n<td dir=\"ltr\" style=\"text-align: left;\" width=\"26\"><strong>QTY.<\/strong><\/td>\n<td dir=\"ltr\" style=\"text-align: left;\" rowspan=\"2\" width=\"59\"><strong>CODE<\/strong><\/p>\n<p>B07024001<\/td>\n<td dir=\"ltr\" style=\"text-align: left;\" rowspan=\"2\" width=\"470\"><strong>DESCRIPTION 5 KG.<\/strong><\/p>\n<p>IHP Cylinder \/ valve assembly<\/td>\n<\/tr>\n<tr dir=\"ltr\">\n<td width=\"26\">1<\/td>\n<td width=\"26\">1<\/td>\n<\/tr>\n<tr dir=\"ltr\">\n<td width=\"26\">2<\/td>\n<td width=\"26\">1<\/td>\n<td width=\"59\">024900390<\/td>\n<td style=\"text-align: left;\" width=\"470\">Cylinder bracket<\/td>\n<\/tr>\n<tr dir=\"ltr\">\n<td width=\"26\">3<\/td>\n<td width=\"26\">1<\/td>\n<td width=\"59\">024100013<\/td>\n<td style=\"text-align: left;\" width=\"470\">Gasket<\/td>\n<\/tr>\n<tr dir=\"ltr\">\n<td width=\"26\">4<\/td>\n<td width=\"26\">1<\/td>\n<td width=\"59\">B06920006<\/td>\n<td style=\"text-align: left;\" width=\"470\">Rubber hose<\/td>\n<\/tr>\n<tr dir=\"ltr\">\n<td width=\"26\">5<\/td>\n<td width=\"26\">2<\/td>\n<td width=\"59\">B07835026<\/td>\n<td style=\"text-align: left;\" width=\"470\">Tube fitting &#8211; straight<\/td>\n<\/tr>\n<tr dir=\"ltr\">\n<td width=\"26\">6<\/td>\n<td width=\"26\">2<\/td>\n<td width=\"59\">B07835028<\/td>\n<td style=\"text-align: left;\" width=\"470\">Tube fitting &#8211; Elbow<\/td>\n<\/tr>\n<tr dir=\"ltr\">\n<td width=\"26\">7<\/td>\n<td width=\"26\">1<\/td>\n<td width=\"59\">B07835037<\/td>\n<td style=\"text-align: left;\" width=\"470\">Cross\u00a0 panel-fitting<\/td>\n<\/tr>\n<tr dir=\"ltr\">\n<td width=\"26\">8<\/td>\n<td width=\"26\">4<\/td>\n<td width=\"59\">B07860006<\/td>\n<td style=\"text-align: left;\" width=\"470\">Pipe bracket (0 8mm)<\/td>\n<\/tr>\n<tr dir=\"ltr\">\n<td width=\"26\">9<\/td>\n<td width=\"26\">2<\/td>\n<td width=\"59\">022700599<\/td>\n<td style=\"text-align: left;\" width=\"470\">Stainless steel tubing (1m)<\/td>\n<\/tr>\n<tr dir=\"ltr\">\n<td width=\"26\">10<\/td>\n<td width=\"26\">1<\/td>\n<td width=\"59\">026200116<\/td>\n<td style=\"text-align: left;\" width=\"470\">Nozzle<\/td>\n<\/tr>\n<tr dir=\"ltr\">\n<td width=\"26\">11<\/td>\n<td width=\"26\">1<\/td>\n<td width=\"59\">024920013<\/td>\n<td style=\"text-align: left;\" width=\"470\">Protection Spring top<\/td>\n<\/tr>\n<tr dir=\"ltr\">\n<td width=\"26\">12<\/td>\n<td width=\"26\">1<\/td>\n<td width=\"59\">B07830005<\/td>\n<td style=\"text-align: left;\" width=\"470\">Cross\u00a0 panel-fitting<\/td>\n<\/tr>\n<tr dir=\"ltr\">\n<td width=\"26\">13<\/td>\n<td width=\"26\">20<\/td>\n<td width=\"59\">B07860004<\/td>\n<td style=\"text-align: left;\" width=\"470\">Binding ties<\/td>\n<\/tr>\n<tr dir=\"ltr\">\n<td width=\"26\">14<\/td>\n<td width=\"26\">1<\/td>\n<td width=\"59\">B07800015<\/td>\n<td style=\"text-align: left;\" width=\"470\">FireDETEC\u00ae Tube red (10m)<\/td>\n<\/tr>\n<tr dir=\"ltr\">\n<td style=\"text-align: right;\" width=\"26\">15<\/td>\n<td style=\"text-align: right;\" width=\"26\">1<\/td>\n<td style=\"text-align: right;\" width=\"59\">B07810014<\/td>\n<td width=\"470\">\n<p style=\"text-align: left;\">End of line gauge<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: left;\"><strong>\u0645\u0634\u062e\u0635\u0627\u062a \u0633\u06cc\u0633\u062a\u0645 \u0627\u0637\u0641\u0627\u0621 \u063a\u06cc\u0631 \u0645\u0633\u062a\u0642\u06cc\u0645:<\/strong><strong>\u00a0<\/strong><\/p>\n<table dir=\"ltr\">\n<tbody>\n<tr>\n<td width=\"98\">\n<p style=\"text-align: left;\">\n<\/td>\n<td style=\"text-align: left;\" colspan=\"2\" width=\"582\"><strong>COMPLETE CO2 SYSTEMS<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"98\"><strong>Product code unfilled<\/strong><\/td>\n<td style=\"text-align: left;\" width=\"291\"><strong>B07504000<\/strong><\/td>\n<td style=\"text-align: left;\" width=\"291\"><strong>B07504004<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"98\"><strong>Product code filled<\/strong><\/td>\n<td style=\"text-align: left;\" width=\"291\"><strong>B07504500<\/strong><\/td>\n<td style=\"text-align: left;\" width=\"291\"><strong>B07504504<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"98\"><strong>Cylinder kit size<\/strong><\/td>\n<td style=\"text-align: left;\" width=\"291\">5 Kg.<\/td>\n<td style=\"text-align: left;\" width=\"291\">10 Kg. \u00d8204mm<\/td>\n<\/tr>\n<tr>\n<td width=\"98\"><strong>Number of nozzles<\/strong><\/td>\n<td style=\"text-align: left;\" width=\"291\">1<\/td>\n<td style=\"text-align: left;\" width=\"291\">2<\/td>\n<\/tr>\n<tr>\n<td width=\"98\"><strong>Cylinder volume<\/strong><\/td>\n<td style=\"text-align: left;\" width=\"291\">6.7 liters<\/td>\n<td style=\"text-align: left;\" width=\"291\">13.4 liters<\/td>\n<\/tr>\n<tr>\n<td width=\"98\"><strong>Cylinder approval<\/strong><\/td>\n<td style=\"text-align: left;\" width=\"291\">\u03c0<\/td>\n<td style=\"text-align: left;\" width=\"291\">\u03c0<\/td>\n<\/tr>\n<tr>\n<td width=\"98\"><strong>Cyl. weight (empty)<\/strong><\/td>\n<td style=\"text-align: left;\" width=\"291\">10 Kg.<\/td>\n<td style=\"text-align: left;\" width=\"291\">21 Kg.<\/td>\n<\/tr>\n<tr>\n<td width=\"98\"><strong>Operating\u00a0\u00a0 Temperature<\/strong><\/td>\n<td style=\"text-align: left;\" width=\"291\">-20\u00b0C to 60\u00b0C<\/td>\n<td style=\"text-align: left;\" width=\"291\">-20\u00b0C to 60\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"98\"><strong>Working pressure<\/strong><\/td>\n<td style=\"text-align: left;\" width=\"291\">60 bar at 20\u00b0C<\/td>\n<td style=\"text-align: left;\" width=\"291\">60 bar at 20\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"98\"><strong>Siphon tube<\/strong><\/td>\n<td style=\"text-align: left;\" width=\"291\">Yes<\/td>\n<td style=\"text-align: left;\" width=\"291\">Yes<\/td>\n<\/tr>\n<tr>\n<td width=\"98\"><strong>Sensor tubing color<\/strong><\/td>\n<td style=\"text-align: left;\" width=\"291\">Red<\/td>\n<td style=\"text-align: left;\" width=\"291\">Red<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>ELECTRICAL CABINET SYSTEMS &#8211; INDIRECT MINIMIZES RISK TO VITAL EQUIPMENT &#8211; #1 Cause of Industrial Fires* &#8211; 75% of total-loss fires start as an electrical fire* &#8211; Helps minimize damage to vital electrical equipment &#8211; Minimizes work stoppage during repairs\/cleanup &#8211; Prevents extensive cleanup if the sprinkler system discharges KEY FEATURES &#8211; A complete, ready-to-install [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1022,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[193,183],"tags":[227,229,226,228,230,217,219],"yst_prominent_words":[],"class_list":["post-1020","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-rotarex-en","category-uncategorized","tag-ihp-system","tag-indirect-automatic-firefiresuppression","tag-indirect-system","tag-local-aplication-system","tag-local-system","tag--local-application-en","tag---en"],"rttpg_featured_image_url":{"full":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"landscape":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"portraits":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp-150x130.jpg",80,69,true],"medium":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"1536x1536":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"2048x2048":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"widget":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",36,20,false],"square":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",180,100,false],"featured":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"featured_large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"extra_large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"portfolio":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"portfolio_small":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"gallery":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"magazine":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"masonry":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"entry_with_sidebar":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"entry_without_sidebar":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"shop_thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",120,67,false],"shop_catalog":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"shop_single":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"woocommerce_thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"woocommerce_single":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp.jpg",233,130,false],"woocommerce_gallery_thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/09\/ihp-100x100.jpg",100,100,true]},"rttpg_author":{"display_name":"imenariaharigh","author_link":"https:\/\/imenariaharigh.com\/en\/author\/imenariaharigh\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/imenariaharigh.com\/en\/brand-catbrands\/rotarex-en\/\" rel=\"category tag\">Rotarex<\/a> <a href=\"https:\/\/imenariaharigh.com\/en\/uncategorized\/\" rel=\"category tag\">Uncategorized<\/a>","rttpg_excerpt":"ELECTRICAL CABINET SYSTEMS &#8211; INDIRECT MINIMIZES RISK TO VITAL EQUIPMENT &#8211; #1 Cause of Industrial Fires* &#8211; 75% of total-loss fires start as an electrical fire* &#8211; Helps minimize damage to vital electrical equipment &#8211; Minimizes work stoppage during repairs\/cleanup &#8211; Prevents extensive cleanup if the sprinkler system discharges KEY FEATURES &#8211; A complete, ready-to-install&hellip;","_links":{"self":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/1020","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/comments?post=1020"}],"version-history":[{"count":3,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/1020\/revisions"}],"predecessor-version":[{"id":1253,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/1020\/revisions\/1253"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/media\/1022"}],"wp:attachment":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/media?parent=1020"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/categories?post=1020"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/tags?post=1020"},{"taxonomy":"yst_prominent_words","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/yst_prominent_words?post=1020"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}