{"id":1065,"date":"2019-08-05T14:20:53","date_gmt":"2019-08-05T09:50:53","guid":{"rendered":"https:\/\/imenariaharigh.com\/%d8%af%d8%aa%da%a9%d8%aa%d9%88%d8%b1-%d9%87%d8%a7%db%8c-%d8%ae%d8%b7%db%8c-%d9%84%db%8c%d8%b2%d8%b1%db%8c-open-path-gas-detector\/"},"modified":"2019-09-21T23:25:05","modified_gmt":"2019-09-21T19:55:05","slug":"open-path-gas-detector","status":"publish","type":"post","link":"https:\/\/imenariaharigh.com\/en\/open-path-gas-detector\/","title":{"rendered":"Open Path Gas Detector"},"content":{"rendered":"<p dir=\"ltr\">The Open Path Gas Detectors include the two series of ds900 and ds700 which we will explain in this post.<\/p>\n<p dir=\"ltr\"><strong>Open Path Gas Detector ds 900 Series Laser Detector:<\/strong><\/p>\n<p dir=\"ltr\">The SafEye Quasar 900 series features the latest open path IR technology that detects a wide range of hydrocarbon gases including alkanes (methane to hexane) and ethylene.<br \/>\nThe model can travel up to 660 feet (200 meters) in length, and you can use Quasar 900 models to protect high-risk installation.<br \/>\nReliability and performance are key, and trust this product with SIL2 verification and performance testing, and having FM and EN standards.<\/p>\n<h3 class=\"tw-data-text tw-ta tw-text-small\" dir=\"ltr\" data-placeholder=\"Translation\"><strong><span lang=\"fa\" tabindex=\"0\">Why Open Path Gas Detectors?<\/span><\/strong><\/h3>\n<h3 class=\"tw-data-text tw-ta tw-text-small\" dir=\"ltr\" data-placeholder=\"Translation\"><span style=\"font-size: 12px;\">Spectrex invented the xenon flash lamp design that revolutionized the open-path gas detection market, which, until then, was plagued by false alarms due to the drawbacks of the previous designs.<br \/>\nNow, Open path detectors complement the use of individual point detectors, take executive action and offer many significant benefits including:<br \/>\n\u2022 Wider area coverage<br \/>\n\u2022 Most likely method to pick up any leak<br \/>\n\u2022 Very high speed of response<br \/>\n\u2022 No unrevealed failure modes<br \/>\n\u2022 Beam block warning<br \/>\n\u2022 Detector location is less critical<br \/>\n\u2022 Size of gas hazard indicated<br \/>\n<\/span><\/h3>\n<h3 dir=\"ltr\" data-placeholder=\"Translation\"><strong>Applications include:<\/strong><\/h3>\n<p dir=\"ltr\" data-placeholder=\"Translation\"><span style=\"font-size: 12px;\">\u2022 Offshore platforms &amp; FPSOs<br \/>\n\u2022 Petrochemical plants<br \/>\n\u2022 Chemical processing plants<br \/>\n\u2022 Gas filling and distribution terminals<br \/>\n\u2022 Gas transport and pipelines<br \/>\n\u2022 Large storage areas &amp; buildings<br \/>\n\u2022 Perimeter monitoring<\/span><\/p>\n<h3 class=\"tw-data-text tw-ta tw-text-small\" dir=\"ltr\" data-placeholder=\"Translation\"><span lang=\"fa\" tabindex=\"0\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-847\" src=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/ds-g-900.pdf.png\" alt=\"ds 900 \u062f\u062a\u06a9\u062a\u0648\u0631 \u0647\u0627\u06cc \u062e\u0637\u06cc \u0644\u06cc\u0632\u0631\u06cc Open Path Gas Detector\" width=\"481\" height=\"296\" srcset=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/ds-g-900.pdf.png 617w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/ds-g-900.pdf-300x185.png 300w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/ds-g-900.pdf-2x1.png 2w\" sizes=\"auto, (max-width: 481px) 100vw, 481px\" \/><br \/>\n<strong>Installation Options<\/strong><br \/>\n<\/span><\/h3>\n<p dir=\"ltr\" data-placeholder=\"Translation\"><strong> <span style=\"font-size: 12px;\">QUASAR OFFERS OPTIONS FOR YOUR INSTALLATION:<\/span><\/strong><br \/>\n\u2022 <span style=\"font-size: 12px;\">0-20mA analog output with HART capability<br \/>\n\u2022 RS485 Modbus, where up to 256 detectors can be linked<\/span><\/p>\n<p>&nbsp;<\/p>\n<h3 dir=\"ltr\" data-placeholder=\"Translation\"><strong>Worldwide Approvals<\/strong><\/h3>\n<p dir=\"ltr\" data-placeholder=\"Translation\"><span style=\"font-size: 12px;\">\u2022 Hazardous area (Zone 1) FM\/FMC, ATEX, IECEx, GOST R Inmetro<br \/>\n\u2022 Performance (3rd party):<br \/>\nFM 6325 approved by FM<br \/>\nEN60079-29-4 tested by FM<br \/>\n\u2022 Reliability:<br \/>\nSIL2 (TUV)<\/span><\/p>\n<h4 dir=\"ltr\" data-placeholder=\"Translation\"><strong>HART<\/strong><\/h4>\n<p dir=\"ltr\" data-placeholder=\"Translation\"><span style=\"font-size: 12px;\">HART capabilities within the Quasar 900 can provide digital communications between the field and the safe area.<br \/>\nThis can provide real time information on the status of an individual detector as well as configuration and historical data of each device, without the need for extra cable cores.<br \/>\nA key feature of HART is that digital signals are transmitted on the same two wires as the 0-20mA current signal.<br \/>\nUseful and useable information available via HART includes:<br \/>\n\u2022 Display set-up<br \/>\n\u2022 Reconfigure set-up \u2013 such as gas<br \/>\ncalibration, heater control, address<br \/>\n\u2022 Display detector status and definition<br \/>\n\u2022 Perform detector diagnostics<br \/>\n\u2022 Troubleshooting<br \/>\n\u2022 View Event Log<\/span><\/p>\n<h2 dir=\"ltr\" data-placeholder=\"Translation\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-849 size-full\" src=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/ds-g-900-2-1.png\" alt=\"ds-g-900-2 \u062f\u062a\u06a9\u062a\u0648\u0631 \u0647\u0627\u06cc \u062e\u0637\u06cc \u0644\u06cc\u0632\u0631\u06cc Open Path Gas Detector\" width=\"504\" height=\"229\" srcset=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/ds-g-900-2-1.png 504w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/ds-g-900-2-1-300x136.png 300w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/ds-g-900-2-1-2x1.png 2w\" sizes=\"auto, (max-width: 504px) 100vw, 504px\" \/><\/h2>\n<h2 class=\"tw-data-text tw-ta tw-text-small\" dir=\"ltr\" data-placeholder=\"Translation\"><span lang=\"fa\" tabindex=\"0\"><strong>Open Path Gas Detector ds 700 Series Laser Detector:<\/strong><\/span><\/h2>\n<p id=\"tw-target-text\" class=\"tw-data-text tw-ta tw-text-small\" dir=\"rtl\" data-placeholder=\"Translation\"><span style=\"font-size: 12px;\"> \u0627\u06cc\u0646 \u062a\u0635\u0648\u06cc\u0631 \u0646\u0634\u0627\u0646 \u0645\u06cc \u062f\u0647\u062f \u06a9\u0647 \u0686\u06af\u0648\u0646\u0647 \u0645\u0627\u062a\u0631\u06cc\u0633 \u0622\u0634\u06a9\u0627\u0631\u0633\u0627\u0632\u0647\u0627\u06cc \u0646\u0648\u0639 \u0646\u0642\u0637\u0647 \u0627\u06cc \u0645\u06cc \u062a\u0648\u0627\u0646\u0646\u062f \u0646\u0634\u062a\u06cc \u0631\u0627 \u0627\u0632 \u062f\u0633\u062a \u0628\u062f\u0647\u0646\u062f \u06cc\u0627 \u062f\u0631 \u0646\u0647\u0627\u06cc\u062a \u0641\u0642\u0637 \u0633\u0637\u062d \u06af\u0627\u0632 \u0631\u0642\u06cc\u0642 \u0634\u062f\u0647 \u0631\u0627 \u0645\u0634\u0627\u0647\u062f\u0647 \u06a9\u0646\u0646\u062f \u062f\u0631 \u062d\u0627\u0644\u06cc \u06a9\u0647 SafEye 700S Open-Path \u060c \u062f\u0631 \u0627\u06cc\u0646 \u062d\u0627\u0644\u062a 20\u066a LEL x 7 m = 1.4 LEL.m \u0631\u0627 \u0627\u0646\u062f\u0627\u0632\u0647 \u0645\u06cc \u06af\u06cc\u0631\u062f.<\/span><\/p>\n<h3 class=\"tw-data-text tw-ta tw-text-small\" dir=\"rtl\" data-placeholder=\"Translation\"><span lang=\"fa\" tabindex=\"0\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-850\" src=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/ds-g-700.png\" alt=\"ds-g-700 \u062f\u062a\u06a9\u062a\u0648\u0631 \u0647\u0627\u06cc \u062e\u0637\u06cc \u0644\u06cc\u0632\u0631\u06cc Open Path Gas Detector\" width=\"669\" height=\"289\" srcset=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/ds-g-700.png 745w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/ds-g-700-300x130.png 300w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/ds-g-700-2x1.png 2w\" sizes=\"auto, (max-width: 669px) 100vw, 669px\" \/><\/span><\/h3>\n<h3 dir=\"ltr\" data-placeholder=\"Translation\"><strong>Open-path Gas Detection Concepts<\/strong><\/h3>\n<p id=\"tw-target-text\" class=\"tw-data-text tw-ta tw-text-small\" dir=\"ltr\" data-placeholder=\"Translation\"><span style=\"font-size: 12px;\">Not all gas clouds are hazardous &#8211; only if a flammable gas cloud or plume is wide enough to allow flame acceleration to speeds greater than 100 m\/sec does it become a significant threat.<\/span><\/p>\n<p class=\"tw-data-text tw-ta tw-text-small\" dir=\"ltr\" data-placeholder=\"Translation\"><span style=\"font-size: 12px;\">\u2022Just as an athlete performing the long jump needs a run-up distance, so too a flame front needs distance to reach the velocities which cause the damaging effects of over pressure, pressure pulse and windage.<\/span><\/p>\n<p class=\"tw-data-text tw-ta tw-text-small\" dir=\"ltr\" data-placeholder=\"Translation\"><span style=\"font-size: 12px;\">\u2022The generally accepted quantity of gas that creates the potential to cause consequential damage if ignited is a cloud of the size 5 m diameter a stoichiometric concentration (about200% LEL).<\/span><\/p>\n<p class=\"tw-data-text tw-ta tw-text-small\" dir=\"ltr\" data-placeholder=\"Translation\"><span style=\"font-size: 12px;\">\u2022 To provide a safety margin, this concentration is halved to 100% LEL. Thus an open path beam traversing this cloud would indicate 5 LEL.m.<\/span><\/p>\n<p class=\"tw-data-text tw-ta tw-text-small\" dir=\"ltr\" data-placeholder=\"Translation\"><span style=\"font-size: 12px;\">\u2022Location of the SafEye 700S Open-Path Gas Detector is less important than with point type detectors as it provides a warning alarm from a diluted gas cloud and does not need to be close to the leakage source.<\/span><\/p>\n<p class=\"tw-data-text tw-ta tw-text-small\" dir=\"ltr\" data-placeholder=\"Translation\"><span style=\"font-size: 12px;\">\u2022 Point type detectors measure gas at their location in terms of % LEL, whereas open-path gas detectors measure the amount of gas anywhere along the length of the path, in terms of the integral of concentration and length (LEL x meters).<\/span><\/p>\n<h3 dir=\"ltr\" data-placeholder=\"Translation\"><strong>Open-Path Applications:<\/strong><\/h3>\n<p dir=\"ltr\" data-placeholder=\"Translation\"><span style=\"font-size: 12px;\">\u2022Offshore Oil &amp; Gas drilling and production<br \/>\n<\/span><span style=\"font-size: 12px;\">\u2022Petrochemical and Chemical storage and \u0630production areas<br \/>\n<\/span><span style=\"font-size: 12px;\">\u2022Storage &amp; loading of hazardous materials and waste areas<br \/>\n<\/span><span style=\"font-size: 12px;\">\u2022Engine &amp; Turbine air intake and modules<br \/>\n<\/span><span style=\"font-size: 12px;\">\u2022LNG-LPG storage, pumping and filling<br \/>\n<\/span><span style=\"font-size: 12px;\">\u2022Fence-line emission monitoring<br \/>\n<\/span><span style=\"font-size: 12px;\">\u2022Storage Tank Farm protection<br \/>\n<\/span><span style=\"font-size: 12px;\">\u2022Paint industries, including paint-booths<br \/>\n<\/span><span style=\"font-size: 12px;\">\u2022Bus terminals (natural gas powered)<br \/>\n<\/span><span style=\"font-size: 12px;\">\u2022Waste disposal and processing<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Open Path Gas Detectors include the two series of ds900 and ds700 which we will explain in this post. Open Path Gas Detector ds 900 Series Laser Detector: The SafEye Quasar 900 series features the latest open path IR technology that detects a wide range of hydrocarbon gases including alkanes (methane to hexane) and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1067,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[254,183],"tags":[269,267,268,262,266],"yst_prominent_words":[],"class_list":["post-1065","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-spectrex-en","category-uncategorized","tag-beam-detector","tag-open-pad-detector","tag-open-path-detector","tag-open-path-gas-detectore-en","tag---spectrex-en"],"rttpg_featured_image_url":{"full":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"landscape":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"portraits":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore-150x130.jpg",80,69,true],"medium":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"1536x1536":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"2048x2048":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"widget":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",36,20,false],"square":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",180,100,false],"featured":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"featured_large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"extra_large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"portfolio":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"portfolio_small":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"gallery":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"magazine":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"masonry":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"entry_with_sidebar":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"entry_without_sidebar":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"shop_thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",120,67,false],"shop_catalog":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"shop_single":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"woocommerce_thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"woocommerce_single":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore.jpg",233,130,false],"woocommerce_gallery_thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/08\/Flame-detectore-100x100.jpg",100,100,true]},"rttpg_author":{"display_name":"imenariaharigh","author_link":"https:\/\/imenariaharigh.com\/en\/author\/imenariaharigh\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/imenariaharigh.com\/en\/brand-catbrands\/spectrex-en\/\" rel=\"category tag\">Spectrex<\/a> <a href=\"https:\/\/imenariaharigh.com\/en\/uncategorized\/\" rel=\"category tag\">Uncategorized<\/a>","rttpg_excerpt":"The Open Path Gas Detectors include the two series of ds900 and ds700 which we will explain in this post. Open Path Gas Detector ds 900 Series Laser Detector: The SafEye Quasar 900 series features the latest open path IR technology that detects a wide range of hydrocarbon gases including alkanes (methane to hexane) and&hellip;","_links":{"self":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/1065","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/comments?post=1065"}],"version-history":[{"count":3,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/1065\/revisions"}],"predecessor-version":[{"id":1255,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/1065\/revisions\/1255"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/media\/1067"}],"wp:attachment":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/media?parent=1065"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/categories?post=1065"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/tags?post=1065"},{"taxonomy":"yst_prominent_words","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/yst_prominent_words?post=1065"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}