{"id":1165,"date":"2019-05-21T20:14:54","date_gmt":"2019-05-21T15:44:54","guid":{"rendered":"https:\/\/imenariaharigh.com\/%da%a9%d9%86%d8%aa%d8%b1%d9%84-%d9%be%d9%86%d9%84-%d8%a7%d8%b7%d9%81%d8%a7-%d8%ad%d8%b1%db%8c%d9%82-nsc\/"},"modified":"2019-09-21T22:37:31","modified_gmt":"2019-09-21T19:07:31","slug":"nsc-firefighting-control-panel","status":"publish","type":"post","link":"https:\/\/imenariaharigh.com\/en\/nsc-firefighting-control-panel\/","title":{"rendered":"NSC Firefighting Control Panel"},"content":{"rendered":"<h3 dir=\"ltr\"><strong>Single zone extinguishing control unit with the FCP Solution F2<\/strong><\/h3>\n<p dir=\"ltr\">The VdS approved fire control panel \u201cSolution F2\u201d, which has successfully established itself within several years on the market can now be used as an extinguishing control system for single areas.<\/p>\n<p dir=\"ltr\">Additionally to the known features:<\/p>\n<h3 dir=\"ltr\">\u00a0NSC Firefighting Control Panel features:<\/h3>\n<ul dir=\"ltr\">\n<li>\n<h5>1\u20132 loops, optional for addressable components by manufacturers either Apollo or Hochiki.<\/h5>\n<\/li>\n<li>\n<h5>Power supply 230 VAC\/24 VDC with 3.5 A.<\/h5>\n<\/li>\n<li>\n<h5>Control panel with membrane keyboard and graphic display.<\/h5>\n<\/li>\n<li>\n<h5>USB- and RS-232 interface.<\/h5>\n<\/li>\n<li>\n<h5>Numerous In\/Outputs.<\/h5>\n<\/li>\n<li>\n<h5>Connectability for fire brigade periphery.<\/h5>\n<\/li>\n<li>\n<h5>RS-485 interface card.<\/h5>\n<\/li>\n<li>\n<h5>Single indication of detector groups.<\/h5>\n<\/li>\n<\/ul>\n<p dir=\"ltr\">The control panel is now capable to combine the standard FCP with an integrated electronic control device for fire extinguishing systems according to EN 12094-1.For this purpose, there is a new control board having a multiplicity of in- and outputs.<\/p>\n<p dir=\"ltr\"><img decoding=\"async\" class=\"img-responsive aligncenter\" src=\"https:\/\/www.nsc-sicherheit.de\/images\/produkte\/loeschsteuerzentrale-f2.jpg\" alt=\"\" \/><\/p>\n<hr dir=\"ltr\" \/>\n<p dir=\"ltr\"><strong>Multiple zone extinguishing control unit with the FCP Solution F1<\/strong><\/p>\n<p dir=\"ltr\">Exactly the same control board, as for the single zone extinguishing control panel \u201dSolution F2\u201d, can be mounted in the \u201cSolution F1\u201d to operate multiple extinguishing zones. nPer each extinguishing zone there is one display board with optional key switch for the essential display and eventually required operating functions.<\/p>\n<p dir=\"ltr\"><a href=\"https:\/\/www.nsc-sicherheit.de\"><img decoding=\"async\" class=\"img-responsive aligncenter\" src=\"https:\/\/www.nsc-sicherheit.de\/images\/produkte\/loeschsteuerzentrale-f1.jpg\" alt=\"\" \/><\/a><\/p>\n<p id=\"tw-target-text\" class=\"tw-data-text tw-text-large tw-ta\" dir=\"ltr\" data-placeholder=\"Translation\">\n<p dir=\"ltr\">Imen Aria Harigh company<span lang=\"en\" tabindex=\"0\">, has NSC distributor, so is able to provide installation and user training with these control panels.<\/span><\/p>\n<p dir=\"ltr\">for more informatuon about NSC control panel:<\/p>\n<ul class=\"tagchecklist\" role=\"list\">\n<li dir=\"ltr\" style=\"text-align: center;\"><a href=\"http:\/\/www.nsc-sicherheit.de\/Download\/Loeschsteuerzentralen_4-seiter-GB_web.pdf\">\u00a0NSC firefighting control panel catalogue<\/a><\/li>\n<li><\/li>\n<li><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Single zone extinguishing control unit with the FCP Solution F2 The VdS approved fire control panel \u201cSolution F2\u201d, which has successfully established itself within several years on the market can now be used as an extinguishing control system for single areas. Additionally to the known features: \u00a0NSC Firefighting Control Panel features: 1\u20132 loops, optional for [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1166,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[185,183],"tags":[374,371,187,372,341,373,200,342],"yst_prominent_words":[],"class_list":["post-1165","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nsc-en","category-uncategorized","tag-fire-fighting-control-panel","tag-nsc-agent-in-iran","tag-nsc-control-panel-en","tag-nsc-distributor-in-iran","tag-nsc-firefighting-control-panel-en","tag-nsc-training","tag--nsc-en","tag----en"],"rttpg_featured_image_url":{"full":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",872,600,false],"landscape":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",872,600,false],"portraits":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",872,600,false],"thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen-150x150.jpg",80,80,true],"medium":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen-300x206.jpg",300,206,true],"large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",872,600,false],"1536x1536":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",872,600,false],"2048x2048":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",872,600,false],"widget":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",36,25,false],"square":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",180,124,false],"featured":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen-670x300.jpg",670,300,true],"featured_large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",872,600,false],"extra_large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",872,600,false],"portfolio":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",495,341,false],"portfolio_small":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",260,179,false],"gallery":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",845,581,false],"magazine":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",545,375,false],"masonry":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",705,485,false],"entry_with_sidebar":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",467,321,false],"entry_without_sidebar":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",615,423,false],"shop_thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",120,83,false],"shop_catalog":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",450,310,false],"shop_single":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",450,310,false],"woocommerce_thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen-300x300.jpg",300,300,true],"woocommerce_single":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen.jpg",600,413,false],"woocommerce_gallery_thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/05\/header-loeschsteuerzentralen-100x100.jpg",100,100,true]},"rttpg_author":{"display_name":"imenariaharigh","author_link":"https:\/\/imenariaharigh.com\/en\/author\/imenariaharigh\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/imenariaharigh.com\/en\/brand-catbrands\/nsc-en\/\" rel=\"category tag\">NSC<\/a> <a href=\"https:\/\/imenariaharigh.com\/en\/uncategorized\/\" rel=\"category tag\">Uncategorized<\/a>","rttpg_excerpt":"Single zone extinguishing control unit with the FCP Solution F2 The VdS approved fire control panel \u201cSolution F2\u201d, which has successfully established itself within several years on the market can now be used as an extinguishing control system for single areas. Additionally to the known features: \u00a0NSC Firefighting Control Panel features: 1\u20132 loops, optional for&hellip;","_links":{"self":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/1165","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/comments?post=1165"}],"version-history":[{"count":2,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/1165\/revisions"}],"predecessor-version":[{"id":1196,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/1165\/revisions\/1196"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/media\/1166"}],"wp:attachment":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/media?parent=1165"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/categories?post=1165"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/tags?post=1165"},{"taxonomy":"yst_prominent_words","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/yst_prominent_words?post=1165"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}