{"id":1172,"date":"2019-01-04T22:57:15","date_gmt":"2019-01-04T19:27:15","guid":{"rendered":"https:\/\/imenariaharigh.com\/%da%a9%d8%a7%d8%b1%d8%aa-%da%a9%d9%86%d8%aa%d8%b1%d9%84-%d9%be%d9%86%d9%84-nsc\/"},"modified":"2019-09-21T22:31:54","modified_gmt":"2019-09-21T19:01:54","slug":"nsc-control-panel-cards","status":"publish","type":"post","link":"https:\/\/imenariaharigh.com\/en\/nsc-control-panel-cards\/","title":{"rendered":"NSC Control Panel Cards"},"content":{"rendered":"<h3 dir=\"ltr\">NSC Solution F1 Control Panel Cards are as below:<\/h3>\n<h4 dir=\"ltr\">Loop Cards :<\/h4>\n<p dir=\"ltr\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-306 aligncenter\" src=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/loop-card.png\" alt=\"nsc loop card \u06a9\u0627\u0631\u062a \u0644\u0648\u067e \" width=\"240\" height=\"160\" srcset=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/loop-card.png 240w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/loop-card-2x1.png 2w\" sizes=\"auto, (max-width: 240px) 100vw, 240px\" \/><\/p>\n<p dir=\"ltr\">Loop card for \u201cSolution F1\u201d with 2 loops \/ 4 stub lines<br \/>\n\u25a0 2 loops \u2013 each maximum 254 detectors \/ modules (Apollo: 2 x 126) \u2013<br \/>\nor alternative 4 stub lines<br \/>\n\u25a0 cable length max. 3,500 m (2 x 2 x 0.8)<br \/>\n\u25a0 8 user programmable open collector outputs<br \/>\n\u25a0 up to 127 loop sounders per loop can be activated at the same time<br \/>\n\u25a0 cable shielding monitored for open and short circuit<br \/>\n\u25a0 Earth fault detection<\/p>\n<h4 dir=\"ltr\">2. (Redundant Loop Cards)<\/h4>\n<p dir=\"ltr\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-308 aligncenter\" src=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/R-loop-card.png\" alt=\"nsc redundant loop card\" width=\"240\" height=\"160\" srcset=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/R-loop-card.png 240w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/R-loop-card-2x1.png 2w\" sizes=\"auto, (max-width: 240px) 100vw, 240px\" \/><\/p>\n<h5 dir=\"ltr\"><\/h5>\n<p dir=\"ltr\">Redundant Loop card for \u201cSolution F1\u201d<br \/>\nwith 2 loops \/ 8 stub lines<br \/>\n\u25a0 As Loop card for \u201cSolution F1\u201d with 2 loops \/ 8 stub lines but<br \/>\nadditionally with 100 % redundancy. This means the micro processor, the<br \/>\nRAM and the operating system memory are doubled on this card.<br \/>\nSo there will be no failure in case of micro processor fault.<\/p>\n<h4 dir=\"ltr\">3. Conventional Cards<\/h4>\n<p dir=\"ltr\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-305 aligncenter\" src=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/conventional-card.png\" alt=\"nsc conventional card \u06a9\u0627\u0631\u062a \u0645\u062a\u0639\u0627\u0631\u0641\" width=\"209\" height=\"145\" srcset=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/conventional-card.png 209w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/conventional-card-1x1.png 1w\" sizes=\"auto, (max-width: 209px) 100vw, 209px\" \/><\/p>\n<p dir=\"ltr\"><span style=\"font-family: 'Open Sans', sans-serif; font-size: 12px; font-style: normal; font-weight: 400;\">Conventional detector card for 8 stub lines<\/span><br \/>\n<span style=\"font-family: 'Open Sans', sans-serif; font-size: 12px; font-style: normal; font-weight: 400;\">\u25a0 compatible to almost all conventional detectors on the market<\/span><br \/>\n<span style=\"font-family: 'Open Sans', sans-serif; font-size: 12px; font-style: normal; font-weight: 400;\">\u25a0 32 detectors per line according German standards<\/span><br \/>\n<span style=\"font-family: 'Open Sans', sans-serif; font-size: 12px; font-style: normal; font-weight: 400;\">\u25a0 8 programmable open collector alarm outputs<\/span><br \/>\n<span style=\"font-family: 'Open Sans', sans-serif; font-size: 12px; font-style: normal; font-weight: 400;\">\u25a0 Earth fault detection<\/span><br \/>\n<span style=\"font-family: 'Open Sans', sans-serif; font-size: 12px; font-style: normal; font-weight: 400;\">\u25a0 Failure mode in case of micro-processor fault<\/span><\/p>\n<h4 dir=\"ltr\">4. (Redundant Conventional Cards)<\/h4>\n<p dir=\"ltr\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-307 aligncenter\" src=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/R-conventional-card.png\" alt=\"nsc redundant conventional card\" width=\"209\" height=\"145\" srcset=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/R-conventional-card.png 209w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/R-conventional-card-1x1.png 1w\" sizes=\"auto, (max-width: 209px) 100vw, 209px\" \/><\/p>\n<h5 dir=\"ltr\"><\/h5>\n<p dir=\"ltr\">Conventional detector card with 100%<br \/>\nredundancy for 8 stub lines<br \/>\n\u25a0 as Conventional detector card for 8 stub lines but with 100 %.<br \/>\nThat means the micro processor, the Ram and the operating system<br \/>\nmemory are doubled on this card. So there will be no failure in case of<br \/>\nmicro processor fault.<\/p>\n<h4 dir=\"ltr\">5. Relay Card<\/h4>\n<p dir=\"ltr\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-309 aligncenter\" src=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/Relay-card.png\" alt=\"nsc relay card \u06a9\u0627\u0631\u062a \u0631\u0644\u0647 \u0627\u0646 \u0627\u0633 \u0633\u06cc\" width=\"189\" height=\"153\" srcset=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/Relay-card.png 189w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/Relay-card-1x1.png 1w\" sizes=\"auto, (max-width: 189px) 100vw, 189px\" \/><\/p>\n<p dir=\"ltr\">Relay card with 8 change over contacts<br \/>\n\u25a0 compatible to F1 fire detection system but usable as a universal<br \/>\ndevice in other systems too<br \/>\n\u25a0 8 programmable change over contacts, each 250 V AC \/ 5 A<\/p>\n<p dir=\"ltr\" style=\"text-align: center;\"><a class=\"mb-button mb-style-raised mb-size-default mb-corners-default mb-text-style-light \" style=\"background-color: #db2121;\" href=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/Solution_F1-12-seiter-GB-2018_web.pdf\">Download NSC Catalog\u00a0<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>NSC Solution F1 Control Panel Cards are as below: Loop Cards : Loop card for \u201cSolution F1\u201d with 2 loops \/ 4 stub lines \u25a0 2 loops \u2013 each maximum 254 detectors \/ modules (Apollo: 2 x 126) \u2013 or alternative 4 stub lines \u25a0 cable length max. 3,500 m (2 x 2 x 0.8) [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1174,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[185],"tags":[187,343,344,345,346,188,347,348,349,350],"yst_prominent_words":[],"class_list":["post-1172","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nsc-en","tag-nsc-control-panel-en","tag-nsc-conventional-card-en","tag-nsc-loop-card-en","tag-nsc-redundant-loop-card-en","tag-nsc-relay-card-en","tag-nsc-solution-f1-en","tag-----nsc-en"],"rttpg_featured_image_url":{"full":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",548,548,false],"landscape":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",548,548,false],"portraits":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",548,548,false],"thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc-150x150.jpg",80,80,true],"medium":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc-300x300.jpg",300,300,true],"large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",548,548,false],"1536x1536":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",548,548,false],"2048x2048":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",548,548,false],"widget":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",36,36,false],"square":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",180,180,false],"featured":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc-548x300.jpg",548,300,true],"featured_large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",548,548,false],"extra_large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",548,548,false],"portfolio":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",400,400,false],"portfolio_small":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",185,185,false],"gallery":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",548,548,false],"magazine":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",375,375,false],"masonry":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",548,548,false],"entry_with_sidebar":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",321,321,false],"entry_without_sidebar":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/01\/nsc.jpg",423,423,false]},"rttpg_author":{"display_name":"imenariaharigh","author_link":"https:\/\/imenariaharigh.com\/en\/author\/imenariaharigh\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/imenariaharigh.com\/en\/brand-catbrands\/nsc-en\/\" rel=\"category tag\">NSC<\/a>","rttpg_excerpt":"NSC Solution F1 Control Panel Cards are as below: Loop Cards : Loop card for \u201cSolution F1\u201d with 2 loops \/ 4 stub lines \u25a0 2 loops \u2013 each maximum 254 detectors \/ modules (Apollo: 2 x 126) \u2013 or alternative 4 stub lines \u25a0 cable length max. 3,500 m (2 x 2 x 0.8)&hellip;","_links":{"self":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/1172","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/comments?post=1172"}],"version-history":[{"count":2,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/1172\/revisions"}],"predecessor-version":[{"id":1176,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/1172\/revisions\/1176"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/media\/1174"}],"wp:attachment":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/media?parent=1172"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/categories?post=1172"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/tags?post=1172"},{"taxonomy":"yst_prominent_words","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/yst_prominent_words?post=1172"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}