{"id":1336,"date":"2019-10-23T21:27:54","date_gmt":"2019-10-23T17:57:54","guid":{"rendered":"https:\/\/imenariaharigh.com\/?p=1336"},"modified":"2021-01-23T09:22:11","modified_gmt":"2021-01-23T05:52:11","slug":"apollo-interfaces","status":"publish","type":"post","link":"https:\/\/imenariaharigh.com\/en\/apollo-interfaces\/","title":{"rendered":"Apollo interfaces"},"content":{"rendered":"<p dir=\"ltr\">Apollo manufactures a comprehensive range of interfaces for systems which enable fire protection solutions to<br \/>\nbe engineered simply and e&#8221;ectively without the need for custom-designed equipment. These interfaces are available for use on Apollo addressable systems.<\/p>\n<h4 dir=\"ltr\"><strong>Apollo XP95 Input \/ Output Unit with Isolator<\/strong><\/h4>\n<h5 dir=\"ltr\"><strong>Product code: <\/strong>55000-847APO<\/h5>\n<p dir=\"ltr\">\n<p dir=\"ltr\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1337\" src=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-847APO.jpg\" alt=\"55000-847APO Apollo interfaces \" width=\"297\" height=\"297\" srcset=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-847APO.jpg 500w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-847APO-150x150.jpg 150w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-847APO-300x300.jpg 300w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-847APO-1x1.jpg 1w\" sizes=\"auto, (max-width: 297px) 100vw, 297px\" \/><\/p>\n<p dir=\"ltr\" style=\"text-align: center;\"><a href=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2021\/01\/55000-847.pdf\">Download Datasheet<\/a><\/p>\n<p dir=\"ltr\">The Input \/ Output Unit provides a voltage-free,\u00a0double pole changeover (DPCO) relay output, a single monitored switch input and an unmonitored, non-polarised input.<\/p>\n<h5 dir=\"ltr\"><strong>Product code: <\/strong>55000-852APO<\/h5>\n<p dir=\"ltr\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1339\" src=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-852.jpg\" alt=\"55000-852 Apollo interfaces \" width=\"286\" height=\"286\" srcset=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-852.jpg 500w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-852-150x150.jpg 150w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-852-300x300.jpg 300w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-852-1x1.jpg 1w\" sizes=\"auto, (max-width: 286px) 100vw, 286px\" \/><\/p>\n<p dir=\"ltr\">The Sounder Control Unit is used to control the operation of a zone of conventional sounders and report their status to the control panel.<\/p>\n<p dir=\"ltr\">The sounder control unit with isolator allows the device to be operated continuously or be pulsed with 1 second on and 1 second off. The Devices can be operated individually or in groups and whichever address mode has been applied, may be synchronised when in pulsed operation.<\/p>\n<p dir=\"ltr\" style=\"text-align: center;\"><a href=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/12\/Product-code-55000-852APO.pdf\">download Datasheet<\/a><\/p>\n<h5 dir=\"ltr\"><strong>Product code:<\/strong>55000-845APO<\/h5>\n<p dir=\"ltr\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1341\" src=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-845APO-500x500.jpg\" alt=\"55000-845APO Apollo interfaces \" width=\"262\" height=\"262\" srcset=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-845APO-500x500.jpg 500w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-845APO-500x500-150x150.jpg 150w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-845APO-500x500-300x300.jpg 300w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-845APO-500x500-1x1.jpg 1w\" sizes=\"auto, (max-width: 262px) 100vw, 262px\" \/><\/p>\n<p dir=\"ltr\" style=\"text-align: center;\"><a href=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/12\/Product-code-55000-845APO.pdf\">download Datasheet<\/a><\/p>\n<p dir=\"ltr\">The Zone Monitor powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis Fire Detectors from a Discovery or XP95 loop. The Zone Monitor with Isolator is loop powered and operates at 17\u201328V DC with protocol pulses of 5\u20139V.<\/p>\n<h5 dir=\"ltr\"><strong>Product code:<\/strong>55000-849APO<\/h5>\n<p dir=\"ltr\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1343\" src=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-849-500x500.jpg\" alt=\"55000-849 Apollo interfaces \" width=\"327\" height=\"327\" srcset=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-849-500x500.jpg 500w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-849-500x500-150x150.jpg 150w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-849-500x500-300x300.jpg 300w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/55000-849-500x500-1x1.jpg 1w\" sizes=\"auto, (max-width: 327px) 100vw, 327px\" \/><\/p>\n<p dir=\"ltr\">The Output Unit provides a voltage free single pole, changeover relay output. It is a simplified version of the Input\/Output Unit without circuitry for monitoring inputs.<\/p>\n<p dir=\"ltr\" style=\"text-align: center;\">\n<p dir=\"ltr\">for more information about Apollo interfaces please chek this site : <a href=\"https:\/\/www.apollo-fire.co.uk\/\">https:\/\/www.apollo-fire.co.uk\/\u00a0\u00a0<\/a><\/p>\n<p dir=\"ltr\">other apollo products on imenariaharigh : <a href=\"https:\/\/imenariaharigh.com\/en\/apollo-en\/\">https:\/\/imenariaharigh.com\/en\/apollo-en\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Apollo manufactures a comprehensive range of interfaces for systems which enable fire protection solutions to be engineered simply and e&#8221;ectively without the need for custom-designed equipment. These interfaces are available for use on Apollo addressable systems. Apollo XP95 Input \/ Output Unit with Isolator Product code: 55000-847APO Download Datasheet The Input \/ Output Unit provides [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1349,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[404,183],"tags":[405,414],"yst_prominent_words":[],"class_list":["post-1336","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-apollo-en","category-uncategorized","tag-apollo-detector","tag-apollo-interface"],"rttpg_featured_image_url":{"full":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"landscape":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"portraits":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface-150x130.jpg",80,69,true],"medium":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"1536x1536":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"2048x2048":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"widget":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",36,20,false],"square":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",180,100,false],"featured":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"featured_large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"extra_large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"portfolio":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"portfolio_small":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"gallery":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"magazine":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"masonry":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"entry_with_sidebar":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"entry_without_sidebar":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"shop_thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",120,67,false],"shop_catalog":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"shop_single":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"woocommerce_thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"woocommerce_single":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface.jpg",233,130,false],"woocommerce_gallery_thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2019\/10\/interface-100x100.jpg",100,100,true]},"rttpg_author":{"display_name":"imenariaharigh","author_link":"https:\/\/imenariaharigh.com\/en\/author\/imenariaharigh\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/imenariaharigh.com\/en\/brand-catbrands\/apollo-en\/\" rel=\"category tag\">Apollo<\/a> <a href=\"https:\/\/imenariaharigh.com\/en\/uncategorized\/\" rel=\"category tag\">Uncategorized<\/a>","rttpg_excerpt":"Apollo manufactures a comprehensive range of interfaces for systems which enable fire protection solutions to be engineered simply and e&#8221;ectively without the need for custom-designed equipment. These interfaces are available for use on Apollo addressable systems. Apollo XP95 Input \/ Output Unit with Isolator Product code: 55000-847APO Download Datasheet The Input \/ Output Unit provides&hellip;","_links":{"self":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/1336","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/comments?post=1336"}],"version-history":[{"count":1,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/1336\/revisions"}],"predecessor-version":[{"id":1345,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/1336\/revisions\/1345"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/media\/1349"}],"wp:attachment":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/media?parent=1336"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/categories?post=1336"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/tags?post=1336"},{"taxonomy":"yst_prominent_words","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/yst_prominent_words?post=1336"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}