{"id":2463,"date":"2020-10-13T15:51:09","date_gmt":"2020-10-13T12:21:09","guid":{"rendered":"https:\/\/imenariaharigh.com\/?p=2463"},"modified":"2021-01-23T10:13:25","modified_gmt":"2021-01-23T06:43:25","slug":"ilq-100-air-sampling-smoke-detector","status":"publish","type":"post","link":"https:\/\/imenariaharigh.com\/en\/ilq-100-air-sampling-smoke-detector\/","title":{"rendered":"ILQ-100 Air sampling Smoke Detector"},"content":{"rendered":"\n<p dir=\"ltr\">The ICAM ILQ detector is a cost-effective Aspirated Smoke Detection (ASD) solution that meets the unique needs of numerous small area applications of up to 100 m\u00b2 (1,000 ft\u00b2). Examples of these include telco landline remote offices, base station controllers, remote base stations, small server rooms, data centre containers, critical equipment, packaged HVAC units, anechoic chambers, pump houses, generator enclosures, signalling huts and modular laboratories, just to name a few.<br>ILQ detectors are suitable for both high and normal sensitivity applications and offer many installation advantages in terms of out-of-box operation, stand-alone functionality and simplified pipe network.<\/p>\n\n\n\n<h3 class=\"has-text-align-left wp-block-heading\"><br>How it Works <\/h3>\n\n\n\n<p dir=\"ltr\">The ILQ detector actively draws air from the protected area through a pipe network where two or four holes are used. The ILQ has two pipe inlets and there are always one or two holes on each pipe. Sampled air is then filtered before being analyzed by the detection chamber. The detection chamber utilizes a laser light source and photoelectric receiver circuitry to detect scattered light caused by the presence of smoke. Alarm (Pre-Alarm &amp; Fire) and Fault conditions are reported by activating the corresponding LEDs on the simple display and dry contact relays. The system allows configuration of both smoke alarm and flow fault thresholds to suit the application needs.<br><\/p>\n\n\n\n<h3 class=\"has-text-align-left wp-block-heading\">Configuration Options<br><\/h3>\n\n\n\n<p dir=\"ltr\">Convenient and expedient configuration of the ILQ detector is available via DIP switches for true out-of-box operation. A USB communication interface is also available for the Xtralis QSC Configuration and Fire System Management Software application.<\/p>\n\n\n\n<h3 class=\"has-text-align-left wp-block-heading\"> Inputs and Outputs <\/h3>\n\n\n\n<p dir=\"ltr\">The ILQ detector provides a programmable General Purpose Input (GPI) for remote Reset, Reset + Disable, Stand-by and External Device (PSU) monitoring functions. Three dry contact relay outputs are available for Alarm and Fault annunciation.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<h3 class=\"has-text-align-left wp-block-heading\">Dimensions<\/h3>\n\n\n\n<div class=\"wp-block-image is-style-default\"><figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-002.jpg\" alt=\"ILQ-100 Air sampling Smoke Detector\" class=\"wp-image-2464\" width=\"566\" height=\"442\" srcset=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-002.jpg 806w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-002-300x234.jpg 300w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-002-768x600.jpg 768w, https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-002-705x551.jpg 705w\" sizes=\"auto, (max-width: 566px) 100vw, 566px\" \/><\/figure><\/div>\n\n\n\n<h3 class=\"has-text-align-left wp-block-heading\">Features<\/h3>\n\n\n\n<p dir=\"ltr\"><br>\u2022 Laser-based absolute smoke detection<br>\u2022 Clean air barrier for optics protection<br>\u2022 Up to 100m\u00b2 (1,000 ft\u00b2) coverage<br>\u2022 Up to 2 x 6 m (20 ft) linear or up to<br>2 x 9 m (30 ft) branched pipe lengths<br>\u2022 2 or 4 Class A \/ VEWFD sampling holes<br>\u2022 Metric\/Imperial pipe inlets<br>\u2022 Pre-alarm, Alarm and Fault Relays<br>\u2022 5 LEDs, Pre-alarm, Fire, Fault, Filter,<br><strong>Power<\/strong><br>\u2022 Monitored on-board filter<br>\u2022 AutoLearn\u2122 Smoke<br>\u2022 General Purpose Input (GPI)<br>\u2022 IP30 enclosure<br>\u2022 Xtralis QSC support<br>\u2022 USB port for PC connection<br>\u2022 Event log<br>\u2022 Low power consumption<br>\u2022 Configuration via DIP switches<br>\u2022 Various mouting options<\/p>\n\n\n\n<h4 class=\"has-text-align-left wp-block-heading\"><br>Listings \/ Approvals<\/h4>\n\n\n\n<p dir=\"ltr\"><br>\u2022 UL<br>\u2022 ULC<br>\u2022 CE<br>\u2022 LPCB<br>\u2022 EN 54-20<\/p>\n\n\n\n<p dir=\"ltr\">Class A, B &amp; C with 4 holes<br>\u2022 Other approvals pending<br>Regional approvals listings and regulatory compliance vary between<br>product models.<\/p>\n\n\n\n<h3 class=\"has-text-align-left wp-block-heading\">Specification<\/h3>\n\n\n\n<p dir=\"ltr\"><br><strong>Supply voltage:<br><\/strong>24 VDC nominal (18 to 30 VDC), externally supplied<br><strong>Current consumption:<br><\/strong>170 mA (quiescent), 190 mA (max)<br><strong>Dimensions (WHD):<br><\/strong>260 mm x 228 mm x 110 mm<br>(10.24 in x 8.98 in x 4.35 in)<br><strong>Weight<\/strong>:<br>1.2 Kg (2.65 lbs)<br><strong>Operating conditions:<br><\/strong>Recommended Detector Ambient: 0\u00b0C to 39\u00b0C(32\u00b0F to 103\u00b0F)*<br><strong>Tested to:<\/strong> -10\u00b0C to 55\u00b0C (14\u00b0F to 131\u00b0F)<br><strong>Humidity<\/strong>: 0% to 95% RH, non-condensingInlet Pipe Size Accepts both metric and imperial standard pipe sizes<br><strong>Metric:<\/strong> 25 mm external diameter<br><strong>Imperial:<\/strong> 1.05 in (3\/4\u201d pipe) external diameter<br><strong>Sampling network:<\/strong><br><strong>Pipe Length:<\/strong> Up to 2 x 6 m (2 x 20 ft) linear, up to 2 x 9 m (2 x 30 ft) branched<br><strong>Sampling Holes:<\/strong> 2 or 4 (1 or 2 per pipe)<br><strong>Sensitivity Range:<\/strong><br>0.005% &#8211; 3.0% obs\/m (0.0015% &#8211; 0.915% obs\/ft)<br><strong>Threshold Setting Range:<\/strong><br><strong>Fire Alarm:<\/strong> 0.15%\/m &#8211; 3%\/m (0.046%\/ft &#8211; 0.915%\/ft)<br><strong>Pre-Alarm: <\/strong>0.1%\/m &#8211; 1.5%\/m (0.03%\/ft &#8211; 0.457%\/ft)<br><strong>Alarm and Flow Delays:<\/strong>0 &#8211; 60 seconds<br><strong>AutoLearn<\/strong>:Smoke<br><strong>Indication<\/strong>:5 LEDs for Pre-alarm, Fire, Fault, Filter and Power<br><strong>IP rating:<\/strong>IP30<br><strong>Filtration:<\/strong>Field replaceable and monitored<br><strong>Flow Monitoring and Reporting:<\/strong>High and Low adjustable<br><strong>Fan control:<\/strong>2 x fans at fixed speed, supervised<br><strong>Relays<\/strong>:3 Relays rated 2 A @ 30 VDC (Pre-alarm, Fire, Fault)<br><strong>PC Connection:<\/strong>USB<br><strong>General Purpose Input (GPI):<\/strong>Reset, Reset + Disable, Stand-by and External Device (PSU) monitoring<br><strong>Event Log:<\/strong>1,000 events<br><strong>Cable termination:<\/strong>Screw terminal blocks (0.2-2.5 sq mm, 30-12 AWG)<br><\/p>\n\n\n\n<h3 class=\"has-text-align-left wp-block-heading\">Ordering Information<\/h3>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>ILQ-100<\/td><td>ICAM ILQ Aspirated Smoke Detector <\/td><\/tr><tr><td>ISP-420<\/td><td>Surface Mount Kit <\/td><\/tr><tr><td>ISP-421<\/td><td>Flush Mount Kit <\/td><\/tr><tr><td>ISP-422<\/td><td>Replacement Filter <\/td><\/tr><tr><td>ISP-422-20<\/td><td>Replacement Filter (20 pieces) <\/td><\/tr><tr><td>ISP-423<\/td><td>Pipe Kit (Metric)<\/td><\/tr><tr><td>ISP-423-US<\/td><td>Pipe Kit (Imperial) <\/td><\/tr><\/tbody><\/table><figcaption><a href=\"https:\/\/imenariaharigh.com\/wp-content\/uploads\/2021\/01\/26107_05_ICAM_ILQ_TDS_A4_IE_lores.pdf\"><strong>Download Datasheet<\/strong><\/a><\/figcaption><\/figure>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The ICAM ILQ detector is a cost-effective Aspirated Smoke Detection (ASD) solution that meets the unique needs of numerous small area applications of up to 100 m\u00b2 (1,000 ft\u00b2). Examples of these include telco landline remote offices, base station controllers, remote base stations, small server rooms, data centre containers, critical equipment, packaged HVAC units, anechoic [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2475,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[220],"tags":[536,537],"yst_prominent_words":[],"class_list":["post-2463","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-xtralis-en","tag--ilq100","tag-537"],"rttpg_featured_image_url":{"full":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"landscape":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"portraits":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001-80x80.jpg",80,80,true],"medium":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001-300x179.jpg",300,179,true],"large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"1536x1536":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"2048x2048":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"widget":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001-36x36.jpg",36,36,true],"square":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001-180x180.jpg",180,180,true],"featured":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"featured_large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"extra_large":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"portfolio":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"portfolio_small":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001-260x185.jpg",260,185,true],"gallery":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"magazine":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"masonry":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"entry_with_sidebar":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"entry_without_sidebar":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"shop_thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",120,72,false],"shop_catalog":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",450,269,false],"shop_single":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",450,269,false],"woocommerce_thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",300,179,false],"woocommerce_single":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001.jpg",486,290,false],"woocommerce_gallery_thumbnail":["https:\/\/imenariaharigh.com\/wp-content\/uploads\/2020\/10\/ICAM_ICAM_ILQ_Datasheet-1-page-001-100x100.jpg",100,100,true]},"rttpg_author":{"display_name":"imenariaharigh","author_link":"https:\/\/imenariaharigh.com\/en\/author\/imenariaharigh\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/imenariaharigh.com\/en\/brand-catbrands\/xtralis-en\/\" rel=\"category tag\">Xtralis<\/a>","rttpg_excerpt":"The ICAM ILQ detector is a cost-effective Aspirated Smoke Detection (ASD) solution that meets the unique needs of numerous small area applications of up to 100 m\u00b2 (1,000 ft\u00b2). Examples of these include telco landline remote offices, base station controllers, remote base stations, small server rooms, data centre containers, critical equipment, packaged HVAC units, anechoic&hellip;","_links":{"self":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/2463","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/comments?post=2463"}],"version-history":[{"count":0,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/posts\/2463\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/media\/2475"}],"wp:attachment":[{"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/media?parent=2463"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/categories?post=2463"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/tags?post=2463"},{"taxonomy":"yst_prominent_words","embeddable":true,"href":"https:\/\/imenariaharigh.com\/en\/wp-json\/wp\/v2\/yst_prominent_words?post=2463"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}