Imen Aria Harigh is NSC Agent in Iran.

As the Agent of NSC control panels, in addition to supplying standard NSC addressable devices, the company is able for:

*Designing

*Installation

*Setting up

* Training in all types of fire alarm and fire alarm systems.

نمایندگی NSC

The “Solution F1-6“ panel has as standard a 24 V DC power supply with max. current of 4.2 A.

The user can connect up to 6 loops – each with 254 loop devices (127 detectors/modules plus 127 loop sounder) –

to this panel and can organize a max. of 512 zones.

There are three standard housings which should be chosen depending on battery backup requirements.

The bigger model “Solution F1-18” has a 24 V DC power supply with max. current of 6.7 A fitted as standard.

This panel can control 18 loops as its maximum

NSC Control Panel model which is NSC Solution F1 has all needed approvals such as VDS and is one of the most powerful control panels in the world.

NSC Solution F1 control panel

NSC CONTROL PANEL

  • ■ Graphics LCD module with 240 x 64 dots
    ■ Integral power supply with 4.2 A or alternative 6.7 A
    ■ Steel housing with brand new touch control panel
    ■ Interface for German Fire Brigade Control Panel
    ■ 3 separate power outputs for transmission device / sounders / strobes
    ■ USB interface for configuration by PC
    ■ Up to 8 programmable push buttons
    ■ Redundant RS-485 interface
    ■ 3 x RS-232 interfaces
    ■ 2 monitored conventional zones in NSC Solution F1
    ■ 16 digital outputs, programmable
    ■ 8 digital inputs, monitored for “open-circuit”
    ■ 4 relay change over contacts, programmable
    ■ Earth fault detection
    ■ Event log with max. 10,000 messages

NSC SOLUTION F1

■ 2 to 18 loops are possible in one standard wall-mounted housing. Analogue addressable detectors and conventional detectors can be mixed in one Fire Control Panel.
■ User-friendly housings because of hinged frames which gives easy access for the technician to the wiring terminals.
■ 32 Bit advanced CPU core – supplied as an upgradeable PCB module! This gives the possibility for smart software solutions and the possibility to change the micro processor very easily in the event of a new – higher performed – model in future or if one model become obsolete. In such a case the main board PCB of the “Solution F1” panel need not be exchanged or upgraded.
■ Generous memory space with 8 MB-Flash and 8 MB-RAM to allow convenient programming of links and customer specified texts.
■ Numerous running modes and detection algorithms are programmable at this new panel. In combination with analogue addressable detectors it can be perfectly adapted to every application of the market.

■ Multi protocol loop cards are available, which means that different analogue addressable detectors can be easily connected. These PCBs are able to check the loop for short circuit and wire break and detect a possible earth fault of the shielding.
■ Guaranteed 100 % compatibility to Hochiki ESP protocol as well as to Apollo XP95 / Discovery protocol in NSC Solution F1.
■ Network by ARCNET. This BUS system distinguishes by multi master ability which leads to a continuously running network even if the master node fails.
■ 8 programmable push buttons allow a user-friendly handling of certain user defined operations.
■ Auto dynamic operating mode by the graphics display with assigned functional push buttons.
■ The texts on front fascia are easy to change for international versions of the “Solution F1”.

 

NSC Solution F1 Control Panel Cards are as below:

Loop Cards :

nsc loop card کارت لوپ

Loop card for “Solution F1” with 2 loops / 4 stub lines
■ 2 loops – each maximum 254 detectors / modules (Apollo: 2 x 126) –
or alternative 4 stub lines
■ cable length max. 3,500 m (2 x 2 x 0.8)
■ 8 user programmable open collector outputs
■ up to 127 loop sounders per loop can be activated at the same time
■ cable shielding monitored for open and short circuit
■ Earth fault detection

2. (Redundant Loop Cards)

nsc redundant loop card

Redundant Loop card for “Solution F1”
with 2 loops / 8 stub lines
■ As Loop card for “Solution F1” with 2 loops / 8 stub lines but
additionally with 100 % redundancy. This means the micro processor, the
RAM and the operating system memory are doubled on this card.
So there will be no failure in case of micro processor fault.

3. Conventional Cards

nsc conventional card کارت متعارف

Conventional detector card for 8 stub lines
■ compatible to almost all conventional detectors on the market
■ 32 detectors per line according German standards
■ 8 programmable open collector alarm outputs
■ Earth fault detection
■ Failure mode in case of micro-processor fault

4. (Redundant Conventional Cards)

nsc redundant conventional card

Conventional detector card with 100%
redundancy for 8 stub lines
■ as Conventional detector card for 8 stub lines but with 100 %.
That means the micro processor, the Ram and the operating system
memory are doubled on this card. So there will be no failure in case of
micro processor fault.

5. Relay Card

nsc relay card کارت رله ان اس سی

Relay card with 8 change over contacts
■ compatible to F1 fire detection system but usable as a universal
device in other systems too
■ 8 programmable change over contacts, each 250 V AC / 5 A

Download NSC Catalog 

Download NSC  Solution F1 control panel Softwareدانلود نرم افزار کنترل پنل NSC

NSC Fire Alarm Control Panel Solution F1

The “Solution F1“ fire control panel range is a new generation, modular and ultra modern fire control panels. These have been developed to meet international standards and to satisfy specific international requirements at the highest level.

  • Modular, intelligent hybrid fire control panel range
  • Supports Hochiki ESP and Apollo XP95 / Discovery detectors
  • 2 – 18 loops in one standard housing
  • Brand new touch control panel
  • Graphics LCD module 240 x 64 as standard included on basic model
  • Integral Power supply 24 V DC with max. 6.7 A or 4.2 A as standard included
  • 32 bit high performance CPU
  • Flash memory up to 8 MB and RAM memory up to 8 MB
  • Many powerful features included
  • NSC Control Panel Configuration software operated via modem or USB interface
  • Full redundant main board and full redundant loop cards as options
  • To get a Download Link, Please Contact Us

در این بخش به معرفی و ارائه نرم افزار های سیستم  اعلام حریق یا نرم افزار کنترل پنل می پردازیم.

همچنین چگونگی کانفیگ کنترل پنل ها را بررسی خواهیم کرد.

نرم افزار کنترل پنل برند هایی از جمله NSC ،C-Tec، Kentec و Zeta.

این نرم افزار ها کاربر را قادر به کانفیگ تمامی کنترل پنل های بالا خواهد ساخت. معرفی لوپ ها یا زون ها، معرفی دتکتور ها، آژیر ها و شستی ها، از طریق نرم افزار های کنترل پنل ها قابل انجام خواهند بود.

پانل اعلام حریق (FACP)، کنترل کننده سیستم اعلام حریق است. پانل اطلاعاتی از دستگاههایی طراحی شده برای مواردی استفاده میکند.  تشخیص و گزارش آتش سوزی، نظارت بر یکپارچگی عملیاتی آنها و فراهم کردن کنترل اتوماتیک تجهیزات و انتقال اطلاعات لازم برای آماده سازی تاسیسات برای آتش. پانل همچنین ممکن است انرژی الکتریکی را برای کار هر دستگاه با رله فراهم کند.

 


دانلود نرم افزار کانفیگ کنترل پنل NSC

معرفی انواع کارت های کنترل پنل NSC

 

نرم افزار های سیستم  اعلام حریق

نرم افزار NSC

در صورت هرگونه سوال جهت ارتباط  با کاشناسان ما، از فرم تماس با ما استفاده نمایید.

Pages

Imen Aria Harigh is NSC Agent in Iran.

As the Agent of NSC control panels, in addition to supplying standard NSC addressable devices, the company is able for:

*Designing

*Installation

*Setting up

* Training in all types of fire alarm and fire alarm systems.

نمایندگی NSC

The “Solution F1-6“ panel has as standard a 24 V DC power supply with max. current of 4.2 A.

The user can connect up to 6 loops – each with 254 loop devices (127 detectors/modules plus 127 loop sounder) –

to this panel and can organize a max. of 512 zones.

There are three standard housings which should be chosen depending on battery backup requirements.

The bigger model “Solution F1-18” has a 24 V DC power supply with max. current of 6.7 A fitted as standard.

This panel can control 18 loops as its maximum

NSC Control Panel model which is NSC Solution F1 has all needed approvals such as VDS and is one of the most powerful control panels in the world.

NSC Solution F1 control panel

NSC CONTROL PANEL

  • ■ Graphics LCD module with 240 x 64 dots
    ■ Integral power supply with 4.2 A or alternative 6.7 A
    ■ Steel housing with brand new touch control panel
    ■ Interface for German Fire Brigade Control Panel
    ■ 3 separate power outputs for transmission device / sounders / strobes
    ■ USB interface for configuration by PC
    ■ Up to 8 programmable push buttons
    ■ Redundant RS-485 interface
    ■ 3 x RS-232 interfaces
    ■ 2 monitored conventional zones in NSC Solution F1
    ■ 16 digital outputs, programmable
    ■ 8 digital inputs, monitored for “open-circuit”
    ■ 4 relay change over contacts, programmable
    ■ Earth fault detection
    ■ Event log with max. 10,000 messages

NSC SOLUTION F1

■ 2 to 18 loops are possible in one standard wall-mounted housing. Analogue addressable detectors and conventional detectors can be mixed in one Fire Control Panel.
■ User-friendly housings because of hinged frames which gives easy access for the technician to the wiring terminals.
■ 32 Bit advanced CPU core – supplied as an upgradeable PCB module! This gives the possibility for smart software solutions and the possibility to change the micro processor very easily in the event of a new – higher performed – model in future or if one model become obsolete. In such a case the main board PCB of the “Solution F1” panel need not be exchanged or upgraded.
■ Generous memory space with 8 MB-Flash and 8 MB-RAM to allow convenient programming of links and customer specified texts.
■ Numerous running modes and detection algorithms are programmable at this new panel. In combination with analogue addressable detectors it can be perfectly adapted to every application of the market.

■ Multi protocol loop cards are available, which means that different analogue addressable detectors can be easily connected. These PCBs are able to check the loop for short circuit and wire break and detect a possible earth fault of the shielding.
■ Guaranteed 100 % compatibility to Hochiki ESP protocol as well as to Apollo XP95 / Discovery protocol in NSC Solution F1.
■ Network by ARCNET. This BUS system distinguishes by multi master ability which leads to a continuously running network even if the master node fails.
■ 8 programmable push buttons allow a user-friendly handling of certain user defined operations.
■ Auto dynamic operating mode by the graphics display with assigned functional push buttons.
■ The texts on front fascia are easy to change for international versions of the “Solution F1”.

 

NSC Solution F1 Control Panel Cards are as below:

Loop Cards :

nsc loop card کارت لوپ

Loop card for “Solution F1” with 2 loops / 4 stub lines
■ 2 loops – each maximum 254 detectors / modules (Apollo: 2 x 126) –
or alternative 4 stub lines
■ cable length max. 3,500 m (2 x 2 x 0.8)
■ 8 user programmable open collector outputs
■ up to 127 loop sounders per loop can be activated at the same time
■ cable shielding monitored for open and short circuit
■ Earth fault detection

2. (Redundant Loop Cards)

nsc redundant loop card

Redundant Loop card for “Solution F1”
with 2 loops / 8 stub lines
■ As Loop card for “Solution F1” with 2 loops / 8 stub lines but
additionally with 100 % redundancy. This means the micro processor, the
RAM and the operating system memory are doubled on this card.
So there will be no failure in case of micro processor fault.

3. Conventional Cards

nsc conventional card کارت متعارف

Conventional detector card for 8 stub lines
■ compatible to almost all conventional detectors on the market
■ 32 detectors per line according German standards
■ 8 programmable open collector alarm outputs
■ Earth fault detection
■ Failure mode in case of micro-processor fault

4. (Redundant Conventional Cards)

nsc redundant conventional card

Conventional detector card with 100%
redundancy for 8 stub lines
■ as Conventional detector card for 8 stub lines but with 100 %.
That means the micro processor, the Ram and the operating system
memory are doubled on this card. So there will be no failure in case of
micro processor fault.

5. Relay Card

nsc relay card کارت رله ان اس سی

Relay card with 8 change over contacts
■ compatible to F1 fire detection system but usable as a universal
device in other systems too
■ 8 programmable change over contacts, each 250 V AC / 5 A

Download NSC Catalog 

Download NSC  Solution F1 control panel Softwareدانلود نرم افزار کنترل پنل NSC

NSC Fire Alarm Control Panel Solution F1

The “Solution F1“ fire control panel range is a new generation, modular and ultra modern fire control panels. These have been developed to meet international standards and to satisfy specific international requirements at the highest level.

  • Modular, intelligent hybrid fire control panel range
  • Supports Hochiki ESP and Apollo XP95 / Discovery detectors
  • 2 – 18 loops in one standard housing
  • Brand new touch control panel
  • Graphics LCD module 240 x 64 as standard included on basic model
  • Integral Power supply 24 V DC with max. 6.7 A or 4.2 A as standard included
  • 32 bit high performance CPU
  • Flash memory up to 8 MB and RAM memory up to 8 MB
  • Many powerful features included
  • NSC Control Panel Configuration software operated via modem or USB interface
  • Full redundant main board and full redundant loop cards as options
  • To get a Download Link, Please Contact Us

در این بخش به معرفی و ارائه نرم افزار های سیستم  اعلام حریق یا نرم افزار کنترل پنل می پردازیم.

همچنین چگونگی کانفیگ کنترل پنل ها را بررسی خواهیم کرد.

نرم افزار کنترل پنل برند هایی از جمله NSC ،C-Tec، Kentec و Zeta.

این نرم افزار ها کاربر را قادر به کانفیگ تمامی کنترل پنل های بالا خواهد ساخت. معرفی لوپ ها یا زون ها، معرفی دتکتور ها، آژیر ها و شستی ها، از طریق نرم افزار های کنترل پنل ها قابل انجام خواهند بود.

پانل اعلام حریق (FACP)، کنترل کننده سیستم اعلام حریق است. پانل اطلاعاتی از دستگاههایی طراحی شده برای مواردی استفاده میکند.  تشخیص و گزارش آتش سوزی، نظارت بر یکپارچگی عملیاتی آنها و فراهم کردن کنترل اتوماتیک تجهیزات و انتقال اطلاعات لازم برای آماده سازی تاسیسات برای آتش. پانل همچنین ممکن است انرژی الکتریکی را برای کار هر دستگاه با رله فراهم کند.

 


دانلود نرم افزار کانفیگ کنترل پنل NSC

معرفی انواع کارت های کنترل پنل NSC

 

نرم افزار های سیستم  اعلام حریق

نرم افزار NSC

در صورت هرگونه سوال جهت ارتباط  با کاشناسان ما، از فرم تماس با ما استفاده نمایید.